PHACO HANDPIECE REPAIR
As soon as we receive the Phaco hand-piece, our technicians begin the diagnosis by completely disassembling the instrument, including the transducer. All connectors, cables, piezoelectric ceramics, electrodes and seals are discarded, to be replaced with fresh components. Next, we inspect and ultrasonically clean the shell housing and remaining transducer components. Then we reassemble the transducer, mate it with a new connector or cable, and test it. Finally, the cable/transducer assembly is fit into the shell housing with all new seals. Before shipping your Phaco hand-piece back to you, we test it one final time and it is autoclaved.

At The Surgical Equipment People, we won’t rest until your hand-piece is in optimal working condition. That’s why we go a step further by completing the following three protective measures on every hand-piece repair:

  • Wire Protection The most vulnerable point of the Phaco handpiece wire is where the cord attaches to the connector or the shell -- this area is strained as the user twists or turns the handpiece during a procedure. The Surgical Equipment People devised a molded strain reliever to provide protection at the connection by distributing the stress along the cord. We apply this design to all handpiece wires*. *(Due to handpiece design, the strain relief cannot be utilized on Storz and Chiron handpieces.)
  • Protection from Moisture Intrusion Phaco handpieces are sealed with an epoxy material at the area where the cord connects to the handpiece. After repeated sterilization, the epoxy beaks down and becomes a primary point for harmful moisture intrusion. The Surgical Equipment People use a potting material that is designed to create a firmer, tighter seal that resists breakdown and prolongs the life of the handpiece.
  • Kevlar Insulation (Protects Wire) A common cause of handpiece failure is wire damage, which is due to a lack of adequate wire protection. The Surgical Equipment People add a layer of Kevlar insulation between both the inner wire and an outer silicone sheathing to strengthen and protect the wire. Kevlar -- the same material used in bullet proof vests -- runs throughout the length of the cord.

The Surgical Equipment People is ISO 9001 certified. ISO 9001 certification is a quality control certification. It is set by international standards. This insures the proper quality repair of every phaco handpiece. Our phaco handpiece service is ISO 9001 certified by TUV ESSEN. All of our handpieces must pass our complete performance and quality testing before release to the customer.


QuickQuote
Click here to get started.

Phaco Handpiece Repair

Diamond Knife Repair


« Back to Repair Services
A – Z Directory
Arthroscope Repair
Battery Repair
Biomedical Equipment Repair
Blood Pressure Monitor Repair
Bronchoscope Repair
Cardiovascular Instrument Repair
Choledochoscope Repair
Colonoscope Repair
Cystoscope Repair
Dermatome Repair
Diamond Knife Care & Cleaning
Diamond Knife Repair
Diamond Knives Repair
Duodenoscope Repair
Electrosurgical Unit Repair
Endoscope Repair
Endoscopic Instrument Repair

Federal Supply Schedule
Feeding Pump Repair
Fiber Optic Light Cable Repair
Flexible Endoscope Repair
Flexible Scope Repair
Footswitch Repair
Gastroscope Repair
General Surgical Equipment Repair
Hand/Foot Power Equipment Repair
Harmonic Scalpel Repair
Hose Repair
Infusion Pump Repair
Insufflator Repair
Laparoscope Repair
Maxillofacial Power Equipment Repair
Medical Equipment Repair
Micro Instrument Repair

Nasolaryngoscope Repair
Needlescope Repair
Neuro Power Equipment Repair
New Medical Equipment Sales
New Surgical Equipment Sales
Ophthalmic Equipment Repair
Oral Power Equipment Repair
Orthopedic Instrument Repair
Orthopedic Power Equipment Repair
Phaco Handpiece Repair
Plastic Power Equipment Repair
Power Equipment Repair
Pulse Oximeter Repair
Refurbished Medical Equipment
Remanufactured Medical Equipment
Rigid Endoscope Repair

Scalpel Repair
Semi-Flexible Endoscope Repair
Semi-Rigid Endoscope Repair
Sigmoidoscope Repair
Surgical Battery Repair
Surgical Equipment Repair
Surgical Equipment Sales
Surgical Generator Repair
Surgical Hose Repair
Surgical Instrument Repair
Surgical Light Source Repair
Syringe Pump Repair
TEE Probe/Ultrasound Repair
Trauma Power Equipment Repair
Ureteroscope Repair
Video Equipment Repair

The Surgical Equipment People | 6626 Central Avenue Pike | Knoxville, TN 37912 | toll free (800) 268-5645 | tel (865) 579-6330 | fax (865) 579-6335